Glaciator X-Stream Testing

Glaciator X-Streams can often experience insufficient cooling, without operators realising the unit is not performing at its best.

Fill out form the below and we will let you know how your unit is performing, and make further recommendations if needed.


Step 1

To check the status of the refrigeration system at any time, use the ICE menu by putting S3 down (dipswitch 12).

The left hand panel will now display the name of the value, while the right hand display will show the temperature.

Use the scroll keys on the right hand display to move through the available values. These values represent the temperatures at specific locations within the refrigeration system.

The abbreviations are as follows: AI – No function at present TA – Ambient temperature EO – Evaporator outlet EI – Evaporator inlet CO – Condenser output CI – Condenser input (newer units will also show Power Hours) 

  1. Turn the machine on
  2. Ensure the ICE button is ON 
  3. Ensure STANDBY is ON
  4. Turn switch S3 ON DO NOT FIRE THE MACHINE
  5. Leave machine for 30 mins to stabilise
  6. Scroll through the ICE menu and record your readings on Step 1 below

Step 2

Now fire the machine at full output (S3 off, set to Level 20, Fog ON) for 5 mins. After 5 mins, keep the machine firing and record your readings (S3 ON) on Step 2 below.